- homeHome chevron_right
- Fire & Safety chevron_right
- Power Supply Stations chevron_right
- SmartLevel SPS
SmartLevel SPS
Power supply units and stations
SPS24060G: 24 V, 1.5 A Power supply station with LCD display and RS485 BUS
The SPS24060G power supply station (24 V, 1.5 A) is designed for fire detection systems and features an LCD display for consulting the event log and viewing detailed fault conditions, such as low battery, mains failure, or dispersion to earth. It is equipped with three individually protected outputs with 4 A current limitation and can be connected to the RS485 Bus of fire control panels. The unit includes a 1.5 A switching module at 27.6 V, housing for two 12 V / 7 Ah batteries, and a compact enclosure (325 × 325 × 80 mm, 3 kg without batteries).
SPS24060S: 24 V, 1.5A Power supply station with LED indicators and Inim loop connection capability
The SPS24060S is a 24 V / 1.5 A power station featuring LED status indicators and direct connection to the loop of INIM control panels, enabling automatic supervision by the panel. It provides fault and mains‑fault outputs, along with a single power output, and is suitable for both stand‑alone operation and system integration. The 1.5 A / 27.6 V switching module supports the installation of two 12 V / 7 Ah batteries. Dimensions: 325 x 325 x 80 mm. Weight: 3 kg (without batteries).
SPS24160G: 24 V, 4 A Power supply station with LCD display and RS485 connection capability
The SPS24160G is a 24 V / 4 A power supply designed to deliver high power and complete control in fire protection systems. Its built‑in LCD display allows monitoring of faults, events, and current draw for each output. It provides three individually protected 4 A outputs and connects directly to the RS‑485 bus of fire control panels. Equipped with a 4 A / 27.6 V switching module, it supports two 12 V / 17 Ah batteries. Increased-size dimensions: 497 x 380 x 87 mm. Weight: 6kg (without batteries).
SPS24160S: 24 V, 4 A Power supply module with LED indicators and Inim loop connection capability
The SPS24160S is the ideal solution for fire protection systems that require high power and loop connection to Inim control panels. With its 4 A output and LED status indicators, the station provides full supervision by the control panel, including fault signals, mains failure, and general fault conditions. It integrates a 4 A / 27.6 V switching module and supports the installation of two 12 V / 17 Ah batteries. Dimensions: 497 x 380 x 87 mm. Weight: 6 kg (without batteries).
This product is available in the following versions

SPS24060G
Stand-alone power supply stations

SPS24060S
Power-supply stations connectable to the loop

SPS24060SR
Power-supply stations connectable to the loop

SPS24160G
Stand-alone power supply stations

SPS24160S
Power-supply stations connectable to the loop

SPS24160SR
Power-supply stations connectable to the loop
Technical specifications
| SPS24060G | SPS24060S | SPS24160G | SPS24160S | |
| Internal switching power-supply module | 1.5 A @ 27.6 V | 1.5 A @ 27.6 V | 4 A @ 27.6 V | 4 A @ 27.6 V |
| Input voltage | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz |
| Maximum current draw from mains (230V~) | 0,5 A | 0,5 A | 1,1 A | 1,1 A |
| Output voltage | nominal 27.6 Vdc – range from 18 to 27.6 Vdc | nominal 27.6 Vdc – range from 18 to 27.6 Vdc | nominal 27.6 Vdc – range from 18 to 27.6 Vdc | nominal 27.6 Vdc – range from 18 to 27.6 Vdc |
| Stability | higher than 1% | higher than 1% | higher than 1% | higher than 1% |
| LCD | Yes | No | Yes | No |
| Ancillary power outputs, each short-circuit protected and 4 A current limited | 3 | 1 | 3 | 1 |
| Tamper/Fault signalling relay output | 1 | 2 | 1 | 2 |
| Built-in battery charger with battery supervision | Yes | Yes | Yes | Yes |
| Battery housing | 2 x 7 Ah 12 V | 2 x 7 Ah 12 V | 2 x 17 Ah 12 V | 2 x 17 Ah 12 V |
| Dimensions (HxWxD) | 322 x 324 x 86 | 322 x 324 x 86 | 497 x 380 x 97 | 497 x 380 x 97 |
| Weight (without battery) | 2.8 kg | 2.8 kg | 6 Kg | 6 Kg |
| Loop connection capability | No | Yes | No | Yes |
| RS485 BUS connection capability | Yes (SmartLoop, SmartLine and SmartLight control panels) | No | Yes (SmartLoop, SmartLine and SmartLight control panels) | No |
Download documentation
lock
lock
lock
lock
lock
lock
lock
lock
lock
lock
keyboard_arrow_down Installation Manual - Materials (9)
lock
lock
lock
lock
lock
lock
lock
keyboard_arrow_down Data Sheet - Materials (6)
keyboard_arrow_down Certificate of Approval (CoA) - Materials (8)
keyboard_arrow_down Certificate of constancy of performance (CoP) - Materials (10)
keyboard_arrow_down EU Declaration of Conformity - Materials (24)
keyboard_arrow_down (EU) Declaration of Performance - Materials (24)
lock
lock
lock
lock
lock
keyboard_arrow_down DWG/DXF drawings - Materials (4)
lock
lock
lock
lock
lock
keyboard_arrow_down PDF Drawings - Materials (4)
Materials (91)
Select all
Deselect all
Other similar products
arrow_back
arrow_forward