FA100

Aspirating smoke detector with LPCB certification

FA100_Contexts01

FA100: aspirating smoke detector with dual channels and dual-light technology

The FA100 aspirating smoke detector is an advanced solution for early fire detection, ideal for critical and high-risk environments. Featuring two independent channels and dual-light technology (infrared and blue), it delivers exceptional sensitivity and outstanding capability to differentiate smoke from non-hazardous particles such as dust or fog – dramatically reducing false alarms. Each channel can be configured for Class A, B or C (EN54-20), covers up to 100 meters and supports up to 50 sampling holes, depending on the selected class.

Compatible with loop or conventional systems, with highly customizable smoke detection

The FA100 is compatible with Inim addressable fire alarm control panels via loop connection, enabling direct monitoring and full alarm management from the control panel. Alternatively, it can be connected to conventional panels through relay outputs and I/O terminals. The system features a common intake fan for both channels and uses interchangeable internal detectors, ensuring easy maintenance and scalable, future-proof design.
FAstudio_Contexts02
FA100
Number of pipes2 intake / 1 exhaust
Maximum number of sampling holes per pipe (Class A)8 holes
Maximum number of sampling holes per pipe (Class B)18 holes
Maximum number of sampling holes per pipe (Class C)51 holes
Maximum overall length of pipes160 m
Maximum distance of a hole from the detector100 m
Recommended drain pipe length0,5 m
Maximum drain pipe length10 m
Primary/auxiliary power supply from external power supplynominal 24 V (from 20 to 30 V)
Maximum current draw400mA @ 24 V
Suction fan speed 1500 - 4750 RPM
Maximum current of I/O terminal outputs15 mA @ 30 V
Maximum relay output current2 A @ 30 V, 30 V
Battery for time/dateCR2032
DisplayGraphic LCD, 192 x 64 pixels, backlit
Box materialABS
Protection gradeIP30
Dimensions190 x 395 x 117 mm
Weight1.95 kg
Temperature-10°C to +55°C
Relative humidity ≤ 93%, non-condensing

Download documentation

lock
lock
lock
keyboard_arrow_down Installation Manual - Materials (2)
lock
lock
lock
keyboard_arrow_down Software Manual - Materials (2)
lock
lock
lock
keyboard_arrow_down Data Sheet - Materials (2)
keyboard_arrow_down Certificate of Approval (CoA) - Materials (1)
keyboard_arrow_down Certificate of Conformity (CoC) - Materials (2)
keyboard_arrow_down Certificate of constancy of performance (CoP) - Materials (1)
keyboard_arrow_down EU Declaration of Conformity - Materials (6)
keyboard_arrow_down UKCA Declaration of Conformity - Materials (2)
keyboard_arrow_down (EU) Declaration of Performance - Materials (2)
keyboard_arrow_down (UKCA) Declaration of Performance - Materials (2)
keyboard_arrow_down Certificate of constancy of Performance (UKCA CoP) - Materials (1)
lock
lock
lock
lock
lock
keyboard_arrow_down DWG/DXF drawings - Materials (4)
lock
lock
lock
lock
lock
keyboard_arrow_down PDF Drawings - Materials (4)
lock
lock
lock
keyboard_arrow_down Software Fire - Materials (2)
Materials (33)
Select all

Interested in these products?

Request more information

Download the Fire & Safety Catalog