- homeHome chevron_right
- Fire & Safety chevron_right
- SmartLevel
SPS SmartLevel Power Stations
Power supplies and power stations
Compatible with

Compatible with

SPS24060G: 24V 1.5A power station with LCD display and RS485 bus
The SPS24060G 24V and 1.5 A power station is designed for fire detection systems and integrates an LCD display for event log consultation and detailed display of faults, such as low batteries, no power or ground fault. It is equipped with 3 individually protected outputs with current limitation to 4 A, which can be connected to the RS485 bus of fire panels.
Includes 1.5 A switching module at 27.6V, housing for two 12V - 7Ah batteries, and compact design (325x325x80 mm, 3 kg without batteries).
SPS24060S: 24V 1.5A power supply with LED indicators and connection on Inim loop
The SPS24060S is a 24V and 1.5 A power station with LED status indicators and direct connection to the loop of Inim control panels for automatic supervision by the control panel. It has fault and network fault output, as well as a single power output, and is suitable for both stand-alone and system-integrated use.
The 1.5A switching module at 27.6V allows the housing of two 12V - 7Ah batteries. Dimensions: 325x325x80 mm. Weight: 3 kg (without batteries).


SPS24160G: 24V 4A power station with LCD display and RS485 connection
The SPS24160G is a 24V and 4 A power supply designed to provide high power and complete control in fire protection systems. The built-in LCD display allows monitoring of faults, events, and power consumption for each output. It offers 3 protected 4A outputs and connects directly to the RS485 bus of control panels.
Equipped with 4A switching module at 27.6V, supports two 12V - 17Ah batteries. Enlarged dimensions: 497x380x87 mm. Weight: 6kg (without batteries).
SPS24160S: 24V 4A power supply with LED indicators and Inim loop connection
The SPS24160S is the ideal solution for fire systems requiring high power and connection on Inim loops. With 4 A output and LED status indicators, the station offers full supervision from the control panel, including fault signals, network absent, and general faults.
It integrates a 4 A switching module at 27.6V, and can accommodate two 12V - 17Ah batteries. Dimensions: 497x380x87 mm. Weight: 6 kg (without batteries).

This product is available in the following versions

SPS24060G / SPS24160G
Stand-alone power stations

SPS24060S / SPS24160S
Power stations that can be connected to the loop
Technical specifications
SPS24060G | SPS24060S | SPS24060SR | SPS24160G | SPS24160S | SPS24160SR | |
Internal switching power supply module | 1.5 A @ 27.6 V | 1.5 A @ 27.6 V | 1.5 A @ 27.6 V | 4 A @ 27.6 V | 4 A @ 27.6 V | 4 A @ 27.6 V |
Input voltage | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz | 230 V~ -15% +10%, 50-60 Hz |
Maximum power consumption from the mains (230V~) | 0,5 A | 0,5 A | 0,5 A | 1,1 A | 1,1 A | 1,1 A |
Output voltage | nominal 27.6 V DC - range from 18 to 27.6 V DC | nominal 27.6 V DC - range from 18 to 27.6 V DC | nominal 27.6 V DC - range from 18 to 27.6 V DC | nominal 27.6 V DC - range from 18 to 27.6 V DC | nominal 27.6 V DC - range from 18 to 27.6 V DC | nominal 27.6 V DC - range from 18 to 27.6 V DC |
Stability | better than 1% | better than 1% | better than 1% | better than 1% | better than 1% | better than 1% |
LCD | Yes | No | No | Yes | No | No |
Auxiliary power outputs, each short-circuit protected and current limited to 4 A | 3 | 1 | 1 | 3 | 1 | 1 |
Relay output for fault/sabotage signaling | 1 | 2 | 2 | 1 | 2 | 2 |
Integrated battery charger and battery supervision | Yes | Yes | Yes | Yes | Yes | Yes |
Battery housing | 2 x 7 Ah 12 V | 2 x 7 Ah 12 V | 2 x 7 Ah 12 V | 2 x 17 Ah 12 V | 2 x 17 Ah 12 V | 2 x 17 Ah 12 V |
Dimensions (HxWxD) | 322 x 324 x 86 | 322 x 324 x 86 | 322 x 324 x 86 | 497 x 380 x 97 | 497 x 380 x 97 | 497 x 380 x 97 |
Weight (without battery) | 2.8 kg | 2.8 kg | 2.8 kg | 6 Kg | 6 Kg | 6 Kg |
Connectable to the loop | No | Yes | Yes | No | Yes | Yes |
Connectable to RS485 BUS | Yes (SmartLoop, SmartLine and SmartLight control panels) | No | No | Yes (SmartLoop, SmartLine and SmartLight control panels) | No | No |
Download documentation
lock
lock
lock
keyboard_arrow_down DWG/DXF drawings - Materials (2)
lock
lock
lock
keyboard_arrow_down PDF Drawings - Materials (2)
lock
lock
lock
lock
lock
lock
lock
lock
lock
lock
lock
lock
keyboard_arrow_down Installation Manual - Materials (11)
lock
lock
lock
lock
lock
lock
lock
lock
lock
lock
lock
keyboard_arrow_down Data Sheet - Materials (10)
keyboard_arrow_down (EU) Declaration of Performance - Materials (24)
keyboard_arrow_down Certificate of Approval (CoA) - Materials (9)
keyboard_arrow_down Certificate of constancy of performance (CoP) - Materials (10)
Materials (92)
Select all
Deselect all
Other similar products
Repeater Previdia C-REP
Temperature-sensitive cables
XP95 and Discovery series mounting bases
SmartLine Central Boards
HP100
arrow_back
arrow_forward